Omron safety
Omron safety Distributor — 28 Genuine SKUs in Stock
Omron's safety systems provide comprehensive protection for personnel and machinery, ensuring compliance with global safety standards without sacrificing productivity. From individual components to fully integrated solutions, our systems are designed to create a safer, more efficient manufacturing environment.
Request safety Quote
Omron safety for Industrial Automation
Hengyixin Automation supplies genuine Omron safety with datasheets, application support, and fast global shipping.
Our engineers help you match the right model to your load profile, communication protocol, and installation environment.
What Sets Our safety Apart
- A complete portfolio including safety controllers, light curtains, switches, and relays
- Certified to meet international safety standards like ISO 13849-1 and IEC 62061
- Flexible and scalable solutions that adapt to any machine size or complexity
- Advanced diagnostics to minimize downtime and simplify troubleshooting
- Seamless integration with standard automation systems for cohesive control
- Innovative designs that enhance operator usability while ensuring maximum protection
Browse safety Products
28 SKUs in stock. Click any product for full specs, datasheets, and pricing.
-
D4B-4111N
Omron D4B-4111N Safety Limit Switch SPDT Metal Enclosure IP67
Omron D4B-4111N is a SPDT safety limit switch with metal enclosure, IP67 protection, direct opening action for industrial safety applications.
-
D4B-4116N
Omron D4B-4116N Safety Limit Switch SPDT Metal Enclosure
Omron D4B-4116N heavy-duty safety limit switch with SPDT snap-action contacts, metal enclosure, and direct-opening mechanism for machine-guarding interlock applications.
-
D4BL-2CRA
Omron D4BL-2CRA Safety Door Switch with Lock Metal Housing
Omron D4BL-2CRA is a safety door switch with solenoid lock, metal housing for harsh environment safety guarding applications.
-
D4BS-25FS
Omron D4BS-25FS Safety Door Switch
Omron D4BS-25FS is a safety door switch for machine guard monitoring with direct opening action for safety interlocks.
-
D4DS-K2
Omron D4DS-K2 Safety-Door Hinge Switch with Vertical Operation Key
Omron D4DS-K2 compact safety-door hinge interlock switch, 1NC/1NO slow-action, vertical key insertion, M20 conduit, for light-duty guard doors on packaging and assembly cells.
-
D4NA-4122
Omron D4NA-4122 Safety Limit Switch with Built-in Amplifier
Omron D4NA-4122 is a safety limit switch with built-in amplifier for enhanced safety monitoring and diagnostics.
-
D4NL-1AFG-B
Omron D4NL-1AFG-B Guard-Lock Safety-Door Switch, Solenoid Lock, 24 VDC
Omron D4NL-1AFG-B guard-lock safety-door switch, solenoid release, 24 VDC, 1NC/1NO + 1NC/1NO dual-contact block, 1,300 N holding force, M20 conduit, IP67.
-
D4NL-4CFG-B
Omron D4NL-4CFG-B Guard-Lock Safety-Door Switch, 2NC, Solenoid Release, 24 VDC
Omron D4NL-4CFG-B guard-lock safety-door switch, 2NC dual-channel safety contacts, solenoid release, 24 VDC, 1,300 N holding force, M20 conduit, IP67.
-
D4NS-1AF
Omron D4NS-1AF Safety Door Switch
Omron D4NS-1AF is a safety door switch for machine guard monitoring with direct opening action for safety interlocks.
-
D4SL-N4EFA-DN
Omron D4SL-N4EFA-DN Safety Door Switch with Lock
Omron D4SL-N4EFA-DN is a safety door switch with solenoid guard lock for machine safety interlocks requiring guard locking.
-
G7SA-2A2B DC24
Omron G7SA-2A2B DC24 Safety Relay 2NO+2NC 24VDC Coil
Omron G7SA-2A2B DC24 is a safety relay with 2NO+2NC contacts, DC24V coil, forced guided contacts for machine safety circuits.
-
G7SA-3A1B
Omron G7SA-3A1B Safety Relay 3NO+1NC Forced Guided Contacts
Omron G7SA-3A1B is a safety relay with 3NO+1NC forced guided contacts for machine safety interlock and monitoring circuits.
-
G7SA-5A1B DC24
Omron G7SA-5A1B DC24 Safety Relay 5NO+1NC 24VDC
Omron G7SA-5A1B DC24 is a safety relay with 5NO+1NC forced guided contacts, DC24V coil for complex machine safety circuits.
-
G7SA-5A1B DC24V
Omron G7SA-5A1B DC24V Safety Relay 5NO+1NC 24VDC
Omron G7SA-5A1B DC24V is a safety relay with 5NO+1NC forced guided contacts, DC24V coil for complex machine safety circuits.
-
G9SA-301 AC-DC24
Omron G9SA-301 Safety Controller 24V AC/DC Compact Safety Unit
Omron G9SA-301 is a compact safety controller with 24V AC/DC supply for machine safety monitoring and control.
-
G9SA-501 AC-DC24V
Omron G9SA-501 AC-DC24V Safety Relay Unit 24V Universal Supply
Omron G9SA-501 is a safety relay unit with 24V AC/DC universal supply for machine safety monitoring.
-
G9SB-200-B AC-DC24V
Omron G9SB-200-B Safety Relay Unit Emergency Stop DIN Rail AC/DC24V
Omron G9SB-200-B is a safety relay unit for emergency stop circuits with 24V AC/DC supply for machine safety.
-
G9SB-3012-A
Omron G9SB-3012-A Safety Relay Module 3PST-NO AC/DC24V
Omron G9SB-3012-A is a safety relay module with 3PST-NO contacts, 24V AC/DC supply for machine safety circuits.
-
G9SE-201
Omron G9SE-201 Safety Relay Unit 2NO 24VDC
Omron G9SE-201 is a safety relay unit with 2NO contacts, 24VDC supply for compact machine safety applications.
-
G9SP-N20S
Omron G9SP-N20S Safety Controller 20 I/O Points
Omron G9SP-N20S is an industrial PLC/controller platform component for deterministic machine sequencing, device coordination, and scalable automation architectures.
-
GD-C1
Omron GD-C1 Barcode Reader Cable
Omron GD-C1 is a connection cable for GD series barcode readers.
-
NX-CSG320
Omron NX-CSG320 Motion Control Unit for NX Series
Omron NX-CSG320 is an industrial PLC/controller platform component for deterministic machine sequencing, device coordination, and scalable automation architectures.
-
NX-SL5500
Omron NX-SL5500 Automation Module/Interface Unit for System Expansion
Omron NX-SL5500 is an automation expansion/interface module for extending I/O, analog capability, or communications within modular control systems.
-
NX-SOD400
Omron NX-SOD400 Safety Output Unit for NX Series
Omron NX-SOD400 is a safety output unit for NX series, providing safety-rated output for machine safety circuits.
-
NX-SOH200
Omron NX-SOH200 Safety Output Module 8-Channel 24VDC SIL3/PLe
Omron NX-SOH200 is an 8-channel safety output module for NX series, providing SIL3/PLe rated safety output.
-
P7SA-10F-ND
Omron P7SA-10F-ND Safety Relay Module for Emergency Stop
Omron P7SA-10F-ND is a safety relay module for emergency stop and safety gate monitoring with 3NC safety outputs.
-
P7SA-10F-ND-PU DC24
Omron P7SA-10F-ND-PU DC24 Safety Relay Module 24VDC
Omron P7SA-10F-ND-PU DC24 is a safety relay module with 24VDC supply for emergency stop and safety gate monitoring.
-
P7SA-14F-ND-PU DC24
Omron P7SA-14F-ND-PU DC24 Safety Relay Module 14-Pin
Omron P7SA-14F-ND-PU DC24 is a 14-pin safety relay module with 24VDC supply for comprehensive machine safety monitoring.
safety FAQs
What safety category do I need for my machine?
Safety categories (ISO 13849-1): Category B: Basic safety, no specific requirements. Category 1: Well-tested components, suitable for low-risk applications. Category 2: Periodic monitoring, for medium-risk. Category 3: Redundant channels with monitoring, for high-risk (most common for industrial machinery). Category 4: Highest level, fault-tolerant, for very high-risk (presses, robots). PL (Performance Level) a-e corresponds to categories. Most machines require Category 3/PL d or Category 4/PL e for safety circuits. Consult risk assessment.
What's the difference between safety relays and safety controllers?
Safety relays (G9SA, G9SB): Fixed functionality, pre-configured for specific applications (E-stop, gate monitoring). Simple wiring, cost-effective for single functions. No programming required. Safety controllers (G9SA-301, NX-SL): Programmable, flexible configuration, multiple safety functions in one unit. Better for complex systems with multiple safety devices. Easier troubleshooting with diagnostics. Choose safety relays for simple applications (1-3 functions), controllers for complex systems (5+ safety devices, multiple zones).
Can I wire multiple E-stop buttons to one safety relay?
Yes, multiple E-stop buttons can be wired in series to a single safety relay input. This is common practice. Important considerations: 1) All E-stops must be normally closed (NC) contacts, 2) Wire in series (daisy-chain), 3) Maximum number depends on relay input capacity (typically 10-20 E-stops), 4) Consider voltage drop for long cable runs, 5) Each E-stop should have positive opening action. For large machines with many E-stops, consider safety controllers with multiple zones for better diagnostics.
What's the difference between D4BL and D4BS safety door switches?
D4BL: Safety door switch with guard lock (solenoid release). Locks guard during machine operation, prevents access until machine stops. Required when hazard continues after stop command (spinning spindle, robot motion). D4BS: Basic safety door switch without lock. Monitors guard position but doesn't lock. Suitable when hazard stops immediately (gravity fall, quick-stop). Choose D4BL for Category 4 applications with time-delay hazards, D4BS for immediate-stop hazards.
Do safety light curtains require a safety relay?
Yes, safety light curtains must connect to a safety relay or safety controller. The safety relay: 1) Monitors light curtain status, 2) Provides redundant shutdown, 3) Monitors for faults (wire break, contact weld), 4) Ensures safe restart. Some light curtains have built-in safety outputs (OSSD) that can directly control contactors, but a safety relay is still recommended for: external device monitoring (EDM), manual reset function, integration with other safety devices (E-stops, gates). Always follow light curtain manufacturer's recommendations.
What's direct opening action and why is it required for safety?
Direct opening action: NC contacts are opened by direct mechanical force from actuator, not by spring. Even if contacts weld together, the actuator physically forces them apart. Required by EN 50205 for safety relays and safety switches. Ensures safety function even with contact weld. Identified by specific symbol on device. All safety-rated devices (E-stops, safety relays, safety switches) must have direct opening action on NC contacts. Never substitute with standard relays for safety circuits.
How do I reset a safety circuit after an E-stop?
Safety circuits require manual reset after safety function activation: 1) Identify and clear the fault (release E-stop, close guard), 2) Press reset button (on safety relay or remote reset), 3) Safety relay checks all inputs are safe, 4) Outputs re-energize, machine can restart. Automatic reset is NOT permitted for safety circuits (except specific applications with risk assessment). Reset button must be: outside hazard zone, clearly visible, protected from accidental operation. Some safety relays support monitored manual reset (checks reset button wiring).
Need a specific Omron safety SKU?
Email sales@hyx-automation.com with your SKU list and quantity — we'll respond same business day with pricing and lead time.
Send Inquiry